FIND THE RIGHT SOLUTION, FASTER - Use our new Product Finders to quickly narrow options & identify your best solutions

Bakken Lost Circulation Case Study: Legion-LCM | Riteks

Legion-LCM Case Study | Riteks

Case study · Legion-LCM · Bakken

Cement to surface, 50% to 100%

Deep surface cement jobs in the Bakken were experiencing severe lost circulation issues and achieving cement to surface roughly only 50% of the time. Replacing a competitive LCM with Legion-LCM increased the success rate to 100%.

Success rates were measured over multiple pads with little to no other changes to the cement job design other than the LCM.

50%
Cement to surface with the competitive LCM
100%
Cement to surface with 4 ppb Legion-LCM in the lead cement

An operator in the Bakken was experiencing severe lost circulation issues on their deep surface cement jobs. Despite using a high concentration of LCM, the lost circulation issues persisted and often led to unsuccessfully returning cement to surface, resulting in low Tops of Cement and requiring remedial or topout cementing.

Challenge

Lowering ECDs and increasing cement excess helped but increased costs and still was not 100% successful.

Solution

Riteks' Legion-LCM was selected to replace the current LCM to improve the success rate of cement to surface. Legion-LCM is an efficient multi-modal lost circulation material capable of bridging and sealing. Its 'all-in-one' concept improves operational efficiency and its efficiency as an LCM provides greater success even at lower concentrations than other LCMs.

Result

Replacing the current LCM with 4 ppb of Legion-LCM in the lead cement improved the success rate of cement to surface from 50% to 100% for multiple pads. The consistent 100% success rate allowed a lower cement excess on future jobs, and eliminated NPT and remedial/topout cement jobs related to the low tops of cement, drastically reducing operator costs.

Legion-LCMFull specifications, recommended loadings, and documentation are on the product page.

View the product page

Concentration by loss type

Select a loss severity to see the Legion-LCM concentration required to plug the associated slot size.

Seepage
 
1 lb/bbl
Partial
 
3 lb/bbl
Severe
 
12 lb/bbl

Slot size association3 mm

Concentrations shown with Riteks Sealing Spacer.

Reference data

Loss TypeSeepagePartialSevere
Slot Size Association0.5 mm1 mm3 mm
Legion Concentration Required to Plug Slot*1 lb/bbl3 lb/bbl12 lb/bbl

*with Riteks Sealing Spacer

Put Legion-LCM on your next pad

Get specifications, recommended loadings, and documentation, or request a sample for your next deep surface job.

281.569.3500 service@riteks.com riteks.com/oilfield-products/legion-lcm
RITEKS INC.