Challenge
Lowering ECDs and increasing cement excess helped but increased costs and still was not 100% successful.
Case study · Legion-LCM · Bakken
Deep surface cement jobs in the Bakken were experiencing severe lost circulation issues and achieving cement to surface roughly only 50% of the time. Replacing a competitive LCM with Legion-LCM increased the success rate to 100%.
Success rates were measured over multiple pads with little to no other changes to the cement job design other than the LCM.
An operator in the Bakken was experiencing severe lost circulation issues on their deep surface cement jobs. Despite using a high concentration of LCM, the lost circulation issues persisted and often led to unsuccessfully returning cement to surface, resulting in low Tops of Cement and requiring remedial or topout cementing.
Lowering ECDs and increasing cement excess helped but increased costs and still was not 100% successful.
Riteks' Legion-LCM was selected to replace the current LCM to improve the success rate of cement to surface. Legion-LCM is an efficient multi-modal lost circulation material capable of bridging and sealing. Its 'all-in-one' concept improves operational efficiency and its efficiency as an LCM provides greater success even at lower concentrations than other LCMs.
Replacing the current LCM with 4 ppb of Legion-LCM in the lead cement improved the success rate of cement to surface from 50% to 100% for multiple pads. The consistent 100% success rate allowed a lower cement excess on future jobs, and eliminated NPT and remedial/topout cement jobs related to the low tops of cement, drastically reducing operator costs.
Legion-LCMFull specifications, recommended loadings, and documentation are on the product page.
View the product pageSelect a loss severity to see the Legion-LCM concentration required to plug the associated slot size.
Slot size association3 mm
Concentrations shown with Riteks Sealing Spacer.
Matching Legion-LCM to your loss zone: see loadings and application detail on the product page.
| Loss Type | Seepage | Partial | Severe |
|---|---|---|---|
| Slot Size Association | 0.5 mm | 1 mm | 3 mm |
| Legion Concentration Required to Plug Slot* | 1 lb/bbl | 3 lb/bbl | 12 lb/bbl |
*with Riteks Sealing Spacer
Get specifications, recommended loadings, and documentation, or request a sample for your next deep surface job.